At AscenZion, effective management of chronic neurological disorders can be achieved:

Without suffering unwanted side-effects of drugs

Without unwanted side-effects of drugs

Without paying hefty medical bills

Safe to apply even in children

Without paying hefty medical bills

Our Technology

AscenZion Neuromodulation leverages on over two decades of cutting-edge research and development in non-invasive neuromodulation by our principal biomedical engineering partner Beijing Yiqi Biotechnology Co. Ltd (“YQ”), to develop AscenZion’s superior range of medical devices.

YQ team of bioengineers led by first- generation founder Mr Zhong Hua (middle)

The ASCENZ-IV Stimulator is HSA approved

The AscenZ Multi-channel Pulsed Current Stimulator is an approved medical device by the Health Science Authority of Singapore that combines the practical application of two well-researched  types of non-invasive neuromodulation methods, Transcranial Pulsed Current Stimulation (tPCS) and Transcutaneous Electrical Nerve Stimulation (TENS), to modulate neuronal signals non-invasively and harness the power of neuroplasticity for delivering breakthrough treatment in neurological diseases, safely and effectively.

Accessories and Spare Parts

Enhance cortical and corticospinal excitability to facilitate neuronal action

Alter functional connectivity and interhemispheric connectivity to enhance brain functions and performance

Induce rhythmic and stochastic resonance that may entrain or desynchronize endogenous brain oscillations for symptom improvement

Electrode

Circular Silver-Fiber Cotton Electrodes

4-cm diameter , 2-capsule pack

Scope of Use

For use on scalp with hair during
transcranial electrical stimulation, compatible with AscenZ Multi-channel Pulse Current Stimulators , AscenZ-IV, AscenZ -VIII and AscenZ-XI.

Self-adhesive Silica Gel Electrodes

4-cm diameter , 2-capsule pack

Scope of Use

For use on the skin of the body to stimulate nerves, muscles and acupoints during transcutaneous electrical nerve stimulation. Compatible with all models of AscenZ Multichannel Pulse Current Stimulators.

Self-adhesive Silica Gel Electrodes

4-cm diameter , 2-capsule pack

Scope of Use

For use on the scalp without hair or on skin of the body that requires smaller contact than 6*9cm silica gel electrodes, to stimulate nerves, muscles and acupoints during transcranial electrical stimulation and transcutaneous electrical nerve stimulation. Compatible with all models of AscenZ Multi-channel Pulse Current Stimulators.

Circular Silver-Fiber Cotton Electrodes

Scope of Aplications

The circular silver-fiber cotton electrode is meant for transcranial stimulation when there is hair on the scalp and would require thorough saturation with saline solution before use. The contacting surface of the electrode is an overlay of our patented Silver-fiber cloth for optimal conduction during tPCS . The circular silver-fiber cotton electrodes are firmly secure to the desired stimulation site on the scalp using our array of head accessories.

Self-adhesive Silica Gel Electrodes

Scope of Aplications

The self-adhesive silica gel electrode is used together with our multi-channel pulsed current stimulators . The conductive silica gel layer may be attached to scalp with no hair during tPCS or skin on the body to stimulate nerves , muscles, acupoints and meridians during TENS.

Self-adhesive Silica Gel Electrodes

Scope of Aplications

This smaller sized self-adhesive silica gel electrode is used when more focused stimulation is required. It may be attached to scalp with no hair during tPCS or skin on the body to stimulate nerves , muscles, acupoints and meridians during TENS. Compatible with all models of AscenZ Multi- channel Pulsed Current Stimulators .

Electrodes for Yiqi Multi-Channel Pulsed Current Stimulator

Product Description Main Components

The product is composed of a conductive silica gel layer as the patient contacting surface and other layers and does contain pharmaceutical components.

Scope of Aplications

The product is used together with the Yiqi Multi-Channel Pulsed Current Stimulator series of products. The conductive silica gel layer is attached to the skin, on the scalp, or on body peripheries such as nerves, muscles, acupoints, and meridians for conducting the electric pulse signal sent by the Yiqi Multi-Channel Pulsed Current Stimulator.

Contraindications

Storage Conditions

Please store product in the temperature range of 5°C – 40°C, and humidity range of 20% – 90%. Do not use the product if the conductive silica gel surface of the electrodes has been compromised eg, melting of silica gel.

Transportation Conditions

Avoid severe impact, high sun exposure and heavy rain splashing on the product during transportation and keep away from pollution sources

Usage Method

  1. Attach the electrodes to the intended skin parts or acupoints and press down tightly, ensuring firm contact
  2. Connect the electrodes to the dual-jack port of the connecting cables of the Yiqi Multi-Channel Pulsed Current Stimulator and you may now start using the electrodes by activating the stimulator
  3. After use, separate the electrodes from the dual-jack port of the connecting cables, then paste the electrodes back into the plastic films sheets before storing
  4. When the electrode has lost its stickiness, please replace the electrodes. The electrodes have a recommended replacement cycle after 30 times of use
  5. For personal hygiene and prevention of cross-contamination, please do not share electrodes when there is more than one user

Electrodes for Yiqi Multi-Channel Pulsed Current Stimulator

Product Description Main Components

The product is composed of a conductive silica gel layer as the patient contacting surface and auxiliary layers and does not contain pharmaceutical components.

Scope of Aplications

The product is used together with the Yiqi Multi-Channel Pulsed Current Stimulator series of products. The conductive silica gel layer is attached to the skin, on the scalp, or on body peripheries such as nerves, muscles, acupoints, and meridians for conducting the electric pulse signal sent by the Yiqi Multi-Channel Pulsed Current Stimulator.

Contraindications

Storage Conditions

Please store the product in the temperature range of 5°C – 40°C, and humidity range of 20% – 90%. Do not use the product if the conductive silica gel surface of the electrodes has been compromised eg, melting of silica gel

Transportation Conditions

Avoid severe impact, high sun exposure and heavy rain splashing on the product during transportation and keep away from pollution sources

Usage Method

  1. Attach the electrodes to the intended skin parts or acupoints and press down tightly, ensuring firm contact
  2. Connect the electrodes to the dual-jack port of the connecting cables of the Yiqi Multi-Channel Pulsed Current Stimulator and you may now start using the electrodes by activating the stimulator
  3. After use, separate the electrodes from the dual-jack port of the connecting cables, then paste the electrodes back into the plastic film sheets before storing
  4. When the electrode has lost its stickiness, please replace the electrodes. The electrodes have a recommended replacement cycle after 30 times of use
  5. For personal hygiene and prevention of cross-contamination, please do not share electrodes when there is more than one user

Electrodes for Yiqi Multi-Channel Pulsed Current Stimulator

Product Description Main Components

The product is composed of a circular rubber casing inset with high density cotton that is overlaid with conductive silver fiber cloth (patient contacting surface).

Scope of Aplications

The product is used together with the Yiqi Multi-Channel Pulsed Current Stimulator series of products. The circular silver fiber cotton electrode is used for scalp with hair during transcranial stimulation. The electrode is pre-soaked in 0.9% NaCl solution and attached to the desired stimulation site on the scalp for conducting the electric pulse signal sent by the Yiqi Multi-Channel Pulsed Current Stimulator.

Contraindications

Storage Conditions

Please store the product in the temperature range of 5°C – 40°C, and humidity range of 20% – 90%. Do not use the product if the conductive silica gel surface of the electrodes has been compromised eg, melting of silica gel.

Transportation Conditions

Avoid severe impact, high sun exposure and heavy rain splashing on the product during transportation and keep away from pollution sources.

Usage Method

  1. Pre-soak the circular silver fiber cotton electrode thoroughly in 0.9% NaCl solution.
  2. Connect a pair of pre-soaked electrodes to the dual-jack port of the connecting cables of the Yiqi Multi-Channel Pulsed Current Stimulator.
  3. Attach the electrodes to the Velcro strap provided in the Yiqi Multi-Channel Pulsed Current Stimulator starter kit, then place the electrodes to the desired stimulation site on the scalp, bounding firmly with the Velcro head strap to ensure firm contact with the scalp.
  4. After use, separate the electrodes from the dual-jack port of the connecting cables, then leave the electrodes to dry sufficiently under sunlight or room temperature before storing.
  5. If there are residual salt crystals on the silver fiber cloth surface of the electrode upon drying, simply dust off.
  6. The electrodes have a recommended replacement cycle after 50 times of use
  7. For personal hygiene and prevention of cross-contamination, please do not share electrodes when there is more than one user

Caps and Head Straps

tPCS Caps
Pediatric tPCS Helmut
tPCS Headstrap

Our Gallery

AscenZ-IV

AscenZ-XI

AscenZ-VIII

AscenZ-II

YQ-PSI